Lightning tower smoothly installed

2022-11-30 15:31:12

On the last day of November, the Hengfengyou Lazta Tower Project was installed. The order lasted for two months. Hengfengyou broke the difficulty of the epidemic and delivered the three lightning protection tower smoothly.

Tower use conditions
1. Basic wind pressure: W0 = 0.4 and 0.7kn/m2
2. Earthquake anti -defense intensity: 8 degrees and small days 8 degrees areas
3. Found carrier capacity: 100 and 200kn/m2
4. Covering thickness: ≤10mm5, verticality: ≤1/1000

Lighting Tower Design basis
1. Building lightning protection design specifications (GB50057-94)
2. Design specifications of towering structure (GBJ135-90)
3. Steel structure design specifications (GB50017-2003)
4. Tower mast steel structure construction and acceptance regulations (CECS80: 2006)

Lightning tower smoothly installed
Lightning tower production and installation
1. All metal parts must be galvanized, and the galvanized layer should be protected when operating.
2. Use galvanized steel pipe tube to make a needle tip. The thickness of the tube wall must not be less than 3mm. The vertical allowable deviation is 3/1000.
4. Welding requirements The welding should be welded. The overlap length must meet the following requirements:
5. Flat steel is twice the width (and at least 3 edges welding).
6. Round steel is 6 times the diameter.
7. When the round steel and flat steel are connected, the length is 6 times the diameter of the round steel.
8. The lightning avoidance tower is generally made of round steel or steel pipe, and its diameter should not be less than the following values:
(1) Independent lightning tower generally uses a diameter of 19mm galvanized round steel.
(2) The lightning protection tower on the roof is a galvanized steel pipe of 25mm diameter.
(3) The top of the water tower uses a galvanized steel pipe with a diameter of 25mm or 40mm
(4) Lightning tower on the top of the chimney uses a diameter of 25mm galvanized round steel or a diameter of 40mm galvanized steel pipe E lightning ring with a diameter of 12mm galvanized round steel or section of 100mm2 galvanized flat steel, and its thickness should be 4mm.
9. The lightning protection tower should be controlled by round steel or welded steel. Its diameter should not be less than the following values: below 1m in length: round steel is 12mm, steel pipe is 20mm, needle length 1-2m: round steel is 16mm, steel pipe is 25mm for 25mm The needle on the top of the chimney: round steel is 20mm, and the steel pipe is 40mm.